AC Drive Control Panel

We are the A reputed manufacturer of AC Drive Control Panel /AC Variable Frequency Drive Control Panel. We manufacture the AC Drive Control Panel /AC Variable Frequency Drive control Panel for various industrial segments.

We herein Dynamic Technologies manufacture the control panels in different IP Ratings form IP – 42 to IP – 65 for different Industry.

Here are the few of them.

  1. Steel Industry
  2. Paper Industry
  3. Sugar Industry
  4. HVAC Industry
  5. Cable Industry
  6. Garment Industry
  7. Printing  Industry
  8. Automobile Industry
  9. Pharmaceutical Industry
  10. Wire Braiding Machine
  11. Combined Wire Drawing Machine

And Many More ………..

Why Use Control Panel for AC Drive?

AC Drive Control Panel /AC Variable Frequency Drive control Panels are majorly understood as a protection and control cabinet for AC Drive.

  1. Safety of AC Drive /AC Variable Frequency Drive (VFD)
    Generally, ac drives / variable frequency drives available in the market by various manufactures are or low IP ratings that is IP 42.AC Drive /AC Variable Frequency Drive (VFD) are Power Electronic device means the electronics and software used to control the electrical load of low voltage to Hi voltage. So we not only have to save this electronics from different environmental conditions but also from electrical surges, spicks and other abnormalities of Raw electricity.More than this we need Breakers and safety devices in the input and output side of the AC Drive /AC Variable Frequency Drive (VFD).

    Various components are used in AC Drive Control Panel /AC Variable Frequency Drive control Panels in Input Like Breaker (to switch on and off the complete system), Semiconductor fuses (to protect from the short circuit), Line chokes.

  1. Various Logical Operations with AC Drive /AC Variable Frequency Drive (VFD)Various components are used in AC Drive Control Panel /AC Variable Frequency Drive control Panels in output Like Contractors, Relays, Output Line Choke and many other components for logical operations.Many more control components, PLC (Programmable Logic Controllers) and other sensing devices are used in AC Drive Control Panel /AC Variable Frequency Drive control Panels to make the circuitry to perform many critical and complex operations in the various Industry.

Conclusion :-

To Perform Various Operation with safety in harsh industrial and environments conditions we need Complete Panel and that is AC Drive control Panel /AC Variable Frequency Drive Control Panel.

AC Drive or AC Variable Frequency Drive or AC VFD are the same terms used for a Power Electronic Instrument used to vary the speed of three-phase induction motor.  The AC drive is consisting of the various circuitry and safety devices.

AC Drive are of various Capacity, Size, Ratings and so various Models for different applications.

As discussed earlier also that the main function of AC VFD is to control the rotational movement of any induction motor, but gradually with the evolution of AC drive,  many safety and an advanced feature are incorporated in this instrument.

Principle of working of AC VFD/ AC Drive: –

Basic Principle of working of  AC Drive /AC Variable Frequency Drive (VFD) is varying the  Frequency of any induction motor with respect to Voltage or this can be described as when Voltage/ Frequency ratio when this ratio changed the rotational speed of the motor will get changed.

This AC Drive /AC Variable Frequency Drive (VFD) has majorly Three components.

  1. The Power Conversion Section.

    In this section input power is fed to the VFD and some protection circuitry is present to protect the further circuitry from the disturbance in Raw Power.

  1. The Control Section.

In this section different type of circuitry is present according to different models for different application in the industry.

  1. The Inverter Section.

Here in this section, the AC is converted into DC and the DC through chopper circuit and come to RC Circuit again
converted into  AC with desired frequency.

AC-Drive-Block-Diagram

Let us first know the various uses of AC Drive / AC VFD in different industry.

Application Of AC Drive/ AC VFD in industry and other areas. 

Approximately in every other industry, Ac drive / VFD is used for motion control, Speed Control or position control. Virtually we cannot imagine any industry without AC Drive / VFD. Let us name some of them.

  1. Steel Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control and position control.
  2. Paper Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control and position control.
  3. Sugar Industry uses AC Drive / VFD for all possible uses i.e. Torque control, Speed Control.
  4. HVAC Industry uses AC Drive / VFD for all possible uses i.e. Speed Control of fan and Torque control for compressors.
  5. Cable Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control and position control.
  6. Garment Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control  and position control.
  7. Printing  Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control and position control.
  8. Automobile Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control and position control.
  9. Pharmaceutical Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control and position control.
  10. Petrochemical Industry uses AC Drive / VFD for all possible uses i.e.  motion control, Speed Control and position control.

So this is the list of some of the industries. The list is big and difficult to accumulate in once.

Benefits Of AC Drive / AC Variable Frequency Drive (VFD)

  1. Motion And Speed Control – Without AC Drive it was very difficult to vary the speed of any machine previously it was done with the different combination of gears which was a time taking process nowadays it is very simple to vary the speed of any motor hence the speed of the machine.
  2.  Energy Savings – As we reduce the speed of any Induction motor with the help of AC Drive / AC Variable Frequency Drive (VFD), actually we reduce the effective Kw Rating of motor so we save electricity in kW.
  3. Low risk of Peak Load Penalty – When we use AC Drive /AC Variable Frequency Drive     (VFD) then there is no possibility of high inrush current because of that particular motor, so      virtually there is no possibility of Peak Load Penalty.
  4. Low risk of thermal and mechanical stress– When we use AC Drive /AC Variable Frequency Drive (VFD) then there is no possibility of high mechanical stress on the mechanical system as well as electrical stress on the Electrical system.
  5. No risk of low Power factor Penalty – When we use AC Drive /AC Variable Frequency Drive (VFD) then there is no possibility of Power factor penalty because in ac drive        when we convert ac to dc and then further DC To AC the power factor will always be unity at the   source end so there will be no chance of low power factor penalty.
  6. Less Expense on wire and cable – When we use AC Drive /AC Variable  Frequency  Drive (VFD) then there will be unity power factor and low inrush currents so there is no requirements of using extra wire and cable size which is the common practice in the industry to   avoid any chances of extra unexpected load on system low voltage or low Power factor.

Variable Speed Capacity Control-  For centrifugal pumps, fans and compressors, the ideal fan (affinity) laws describe how speed affects flow, head and power consumption (Table -1 ).

Table -1. Effects of Changes in Fan Speed

Flow changes linearly with speed Flow Rate2 = Flow Rate1 x (RPM2/RPM1)
Head varies as the speed squared Lift2 = Lift1 x (RPM2/RPM1)2
Power varies as the speed cubed Power2 = Power1 x (RPM2/RPM1)3


AC Drive As starter –  

Use of  AC Drive /AC Variable Frequency Drive (VFD) as a starter is a wise move because if we compare the AC Drive with other types of starters we see that it is a drastic difference in inrush current.

We are trying to explain this with the help of following chart.

Sr. No. Type Of Starter % OF Full Load Current
1. AC Drive / Variable Frequency Drive (VFD) 100 %
2. Star / delta Starter 200%- 300%
3. Solid State Soft Starter 200%-@250%
4. Auto Transformer Starter 450%-500%
5. DOL Starter 800%-900%

Conclusion:-

By  Above chart And Discussed Facts here is the concussion

  1. AC Drive /AC Variable Frequency Drive (VFD) is the most energy-efficient means of control.
  2. AC Drive /AC Variable Frequency Drive (VFD) Reduce the thermal and mechanical stress on the system.
  3. AC Drive /AC Variable Frequency Drive (VFD) Provides the highest power factor and there is no  need of separate capacitors or power factor correction panels in the system.
  4. AC Drive /AC Variable Frequency Drive (VFD) provides low Kva and saves energy.
  5. AC Drive /AC Variable Frequency Drive (VFD) saves the capital cost involvements in not only    generation back up but also in wire and cable sizing.